Questions? Chat Now

Columbia Dual Channel NMES

$1,335.36
Product Symbol Definitions
  • Latex Product

    This product contains natural rubber latex which may cause allergic reactions.

  • Hygiene Product

    For health reasons we are unable to accept returns or exchanges of hygiene products.

  • Product Requires Truck Delivery

    This item is considered dimensionally oversized parcel or requires truck delivery. Additional shipping charges will be calculated at time of order.

  • Product Contains Hazardous Materials

    This item is classified as hazardous materials. Can ship ground only - restricted from air. Additional shipping surcharge will be added at time of order.

  • Bariatric Product

    This product has a Bariatric rating.

  • If you have any questions please contact customer support at: 1.800.323.5547 or Email at:

to view when this item will be in stock & ready to ship. Please select an address

OTHER ADDRESSES

Company or Name Street Address 2 City State Zip
Item #
Please choose an option
Catalog #
Please choose an option
  • Works with all styles of Dysphagia electrodes cleared by the FDA
  • During operation, temperature should be between 41° F and 104° F, atmospheric pressure between 700hPa and 1031Pa, and humidity between 15% and 95%
  • For storing or transporting this device, the temperature should be between -6° F and 131° F, the atmospheric pressure should be between 700hPa - 1031hPa, and humidity should be between 5% and 95%
  • Sized 2.6" x 5" x 1.1" and weighing 7.5 oz. without batteries
  • For medical professional use only
More Info
Delivery Over 99% Order Accuracy.
Checkout

Initial Set-Up

Set up your device using four simple steps. First, insert batteries by opening the compartment on the back of your device. Then, connect lead wires to the device, making sure the wires are fully inserted. Next, connect the lead wires to the electrodes. Know that any of the electrodes can be connected to any of the lead wires. Lastly, determine the correct electrode placement by referring to your guide, to ensure a safe and effective therapy session.

Device Kit Options

Choose the option that best fits your needs. The Columbia 6000 NMES Dysphagia device kit includes 10 sets of Columbia 600 1” diameter pig tail connection electrodes. There is also the Columbia 6000B NMES Dysphagia device kit that has 10 sets of Columbia 600B .86” diameter mini-snap connection electrodes with a butterfly patch.

Specifications

The Columbia 6000 Device has two therapy channels, one preset therapy program, and uses the NMES as the therapy output mode. The available waveform characteristics are square, symmetrical, bi-phasic, and a constant current output. All the values of the output voltage range are VAC P2P with a maximum of 100 volts and no load.The output current range with all values being mA P2P are dual intensity potentiometers :25 mA P2P and they have a constant current regulation from 0-4000 ohms load minimum. The pulse width range is 300 microseconds and the pulse frequency range is 80 Hz. This device has an internal power supply of (4) AA Cells (1.5V). Do not use lithium cell greater than 1.6V.

Details
Brand Columbia Scientific
  • Works with all styles of Dysphagia electrodes cleared by the FDA
  • During operation, temperature should be between 41° F and 104° F, atmospheric pressure between 700hPa and 1031Pa, and humidity between 15% and 95%
  • For storing or transporting this device, the temperature should be between -6° F and 131° F, the atmospheric pressure should be between 700hPa - 1031hPa, and humidity should be between 5% and 95%
  • Sized 2.6" x 5" x 1.1" and weighing 7.5 oz. without batteries
  • For medical professional use only
More Info